Fire Rated Systems - Walls - Two Way FRR - Timber Frame Walls
Specification Number Load Bearing Capacity STC IIC Fire Resistance Rating Lining Requirements Weight PDF CAD Files
GBT15 NLB 36 0 -/15/15 1 layer 10mm GIB® Standard 22 PDF Specification CAD Drawings Page
GBTL 15 LB 36 0 15/15/15 1 layer 10mm GIB® Standard 22 PDF Specification CAD Drawings Page
GBT 30a NLB 36 0 -/30/30 1 layer 10mm GIB Fyreline® 22 PDF Specification CAD Drawings Page
GBTL 30 LB 36 0 30/30/30 1 layer 10mm GIB Fyreline® 22 PDF Specification CAD Drawings Page
GBT 30b NLB 36 0 -/30/30 1 layer 13mm GIB® Standard 26 PDF Specification CAD Drawings Page
GBTL 30b LB 36 0 30/30/30 1 layer 13mm GIB® Standard 26 PDF Specification CAD Drawings Page
GBT 60a NLB 36 0 -/60/60 1 layer 13mm GIB Fyreline® 27 PDF Specification CAD Drawings Page
GBTL 60 LB 36 0 60/60/60 1 layer 13mm GIB Fyreline® 27 PDF Specification CAD Drawings Page
GBTL 60b LB 42 0 60/60/60 2 layers 10mm GIB Fyreline® 39 PDF Specification CAD Drawings Page
GBT 90 NLB 37 0 -/90/90 1 layer 16mm GIB Fyreline® 36 PDF Specification CAD Drawings Page
GBTL 90 LB 37 0 90/90/90 1 layer 16mm GIB Fyreline® 36 PDF Specification CAD Drawings Page
GBT 120a NLB 43 0 -/120/120 2 layers 13mm GIB Fyreline® 47 PDF Specification CAD Drawings Page
GBT 120b NLB 35 0 -/120/120 1 layer 19mm GIB Fyreline® 43 PDF Specification CAD Drawings Page
GBTL 120 LB 46 0 120/120/120 2 layers 16mm GIB Fyreline® 65 PDF Specification CAD Drawings Page
GBT 180 NLB 46 0 -/180/180 2 layers 16mm GIB Fyreline® 65 PDF Specification CAD Drawings Page
Fire Rated Systems - Walls - Two Way FRR - Steel Frame Walls
Specification Number Load Bearing Capacity STC IIC Fire Resistance Rating Lining Requirements Weight PDF CAD Files
GBSL 15 LB 34 0 15/15/15 1 layer 13mm GIB® Standard 22 PDF Specification CAD Drawings Page
GBS 30 NLB 34 0 -/30/30 1 layer 13mm GIB® Standard 22 PDF Specification CAD Drawings Page
GBSL 30a LB 41 0 30/30/30 1 layer 16mm GIB Fyreline® 29 PDF Specification CAD Drawings Page
GBSL 30b LB 44 0 30/30/30 2 layers 10mm GIB Fyreline® 32 PDF Specification CAD Drawings Page
GBS 60 NLB 34 0 -/60/60 1 layer 13mm GIB Fyreline® 23 PDF Specification CAD Drawings Page
GBSL 60a LB 42 0 60/60/60 1 layer 19mm GIB Fyreline® 32 PDF Specification CAD Drawings Page
GBSL 60b LB 45 0 60/60/60 2 layers 13mm GIB Fyreline® 38 PDF Specification CAD Drawings Page
GBS 90 NLB 41 0 -/90/90 1 layer 16mm GIB Fyreline® 29 PDF Specification CAD Drawings Page
GBSL 90 LB 45 0 90/90/90 1 layer 16mm GIB Fyreline® + 1 layer 13mm GIB Fyreline® 42 PDF Specification CAD Drawings Page
GBS 120 NLB 42 0 -/120/120 1 layer 19mm GIB Fyreline® 32 PDF Specification CAD Drawings Page
GBS 240 NLB 44 0 -/240/240 4 layers 19mm GIB Fyreline® (Refer to specification for layout) 65 PDF Specification CAD Drawings Page
Fire Rated Systems - Universal Walls - One Way FRR - Timber or Steel Frame
Specification Number Load Bearing Capacity STC IIC Fire Resistance Rating Lining Requirements Weight PDF CAD Files
GBUW 120 LB/NLB 0 0 (120)/120/120 2 layers 19mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUW 15 LB/NLB 0 0 (15)/15/15 1 layer 13mm GIB® Standard 0 PDF Specification CAD Drawings Page
GBUW 30a LB/NLB 0 0 (30)/30/30 1 layer 16mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUW 30b LB/NLB 0 0 (30)/30/30 2 layers 10mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUW 60a LB/NLB 0 0 (60)/60/60 2 layers 13mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUW 90 LB/NLB 0 0 (90)/90/90 1 layer 16mm GIB Fyreline® + 1 layer 19mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUW 60b LB/NLB 0 0 (60)/60/60 1 layer 16mm GIB Fyreline® + 1 layer 13mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
Fire Rated Systems - Floor/Ceiling Systems
Specification Number Load Bearing Capacity STC IIC Fire Resistance Rating Lining Requirements Weight PDF CAD Files
GBFC 15 LB 38 31 15/15/15 Timber joists with 1 layer 10mm GIB Ultraline® or 13mm GIB® Standard 40 PDF Specification CAD Drawings Page
GBFC 45 LB 39 32 45/45/45 Timber joists with 1 layer 13mm GIB Fyreline® 44 PDF Specification CAD Drawings Page
GBCJ 45 LB 39 32 45/45/45 Composite joists with 1 layer 13mm GIB Fyreline® 40 PDF Specification CAD Drawings Page
GBFC 60 LB 39 32 60/60/60 Timber joists with 1 layer 16mm GIB Fyreline® 46 PDF Specification CAD Drawings Page
GBCJ 60 LB 39 32 60/60/60 Composite joists with 1 layer 16mm GIB Fyreline® 44 PDF Specification CAD Drawings Page
GBFC 90 LB 41 34 90/90/90 Timber joists with 2 layers 16mm GIB Fyreline® 63 PDF Specification CAD Drawings Page
GBFC 120 LB 0 0 120/120/120 Timber or steel joists with 2 layers 19mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
Fire Rated Systems - Floor/Ceiling Systems - Suspended Grid
Specification Number Load Bearing Capacity STC IIC Fire Resistance Rating Lining Requirements Weight PDF CAD Files
GBSC 60a LB 53 43 60/60/60 Timber joists with USG ScrewFix™ suspension system & 2 layers 13mm GIB Fyreline® 60 PDF Specification CAD Drawings Page
GBSC 30 LB 48 43 30/30/30 Timber joists with USG ScrewFix™ suspension system & 1 layer 13mm GIB Fyreline® (back blocked) 50 PDF Specification CAD Drawings Page
GBSC 60b LB 50 43 60/60/60 Timber joists with USG Drywall Grid suspension system and 1 layer of 16mm GIB Fyreline® 54 PDF Specification CAD Drawings Page
GBSC 90 LB 53 43 90/90/90 Timber joists with USG Drywall Grid suspension system & 1 layer of 13mm GIB Fyreline® + 1 layer of 16mm GIB Fyreline® 64 PDF Specification CAD Drawings Page
Fire Rated Systems - Universal Ceilings - One Way FRR - Timber or Steel Frame
Specification Number Load Bearing Capacity STC IIC Fire Resistance Rating Lining Requirements Weight PDF CAD Files
GBUC 15 LB/NLB 0 0 (15)/15/15 1 layer 13mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUC 30 LB/NLB 0 0 (30)/30/30 1 layer 16mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUC 45 LB/NLB 0 0 (45)/45/45 2 layers 13mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUC 60 LB/NLB 0 0 (60)/60/60 1 layer 16mm GIB Fyreline® + 1 layer 13mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
GBUC 90 LB/NLB 0 0 (90)/90/90 2 layers 19mm GIB Fyreline® 0 PDF Specification CAD Drawings Page
Fire Rated Systems - Fire Rated Steel Beams and Columns (GIB Fyreline® Linings on timber strapping or steel clip & channel)
Specification Number Load Bearing Capacity STC IIC Fire Resistance Rating Lining Requirements Weight PDF CAD Files
0 0 0 n/a CAD Drawings Page